Technical Description, Installation, Operation and Maintenance Instructions

NextPage
  • 1
  • 2
  • 3
  • 4
  • 5

Advertisem*nt

JP FJH-4/1C-E TECHNICAL DESCRIPTION, INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Pdf Download (1)

Related Manuals for JP FJH-4/1C-E

  • Heater JP 4F400212C01 Technical Description, Installation, Operation And Maintenance Instructions

    Fuel stove and air integrated parkingheater (12 pages)

Summary of Contents for JP FJH-4/1C-E

  • Page 1 JP Heater 6KW Diesel Air & Water Integrated Heater Technical Description, Installation, Operation and Maintenance Instructions...
  • Page 2 JP Heater Production Type Order No. Diesel Air & Water Integrated Heater DC12V/220VAC 4W200512C11 Version: June 14, 2019...
  • Page 3 JP Heater Foreword Thank you for using the J P pa rking heater This manual describes the technical description, installation, operation and maintenance instructions for the parking heater. To ensure the correct use of the heater please read this manual carefully before installation and use.
  • Page 5 JP Heater 1.Application FJH-4/1C-E Model Air & Water Integrated heater (hereinafter referred to as heater) is a special heater for caravan that integrates hot water and warm air. This heater cannot be used in bus or dangerous goods carriers. 2. Main Technical Data...
  • Page 6 JP Heater Rated Voltage DC12V Operating Voltage Range DC10.5V~16V Short-term Maximum Power 8-10A Consumption Average Power Consumption 1.8-4A Fuel Diesel Diesel Heat Power (W) 2000 4000 Fuel Consumption (g/H) Quiescent Current Warm Air Delivery Volume 287max m3/H Water Tank Capacity Maximum Pressure of Water 2.8bar...
  • Page 7 JP Heater Table 1 off first during the power adjustment phase. 3. Function In hot water working mode,diesel mode or electrical mode is used to heat the tank。The tank temperature can The heater is a hot water and warm air integrated machine, be set to 40°C or 60°C.
  • Page 8 JP Heater -- Thermal objects (such as spray cans) or flammable -- If the water heater is not in use, in order to avoid the materials/liquids should not be stored in the same danger of frost, drain the water from the water heater. The...
  • Page 9 JP Heater --Modification of exhaust lines and accessories 5.Heater Installation The typical installation of the heater is shown in --Do not follow the operating installation instructions Figure 1. --Do not use our company's special accessories Figure 1 Figure 1 ★ Must be installed and repaired by professionals...
  • Page 10 JP Heater Heater installation Figure 3. Figu Figure 2 1. 12V Power cord 2. LCD switch Lead wire 3. LCD switch back cover 4. LCD switch bracket 5. Cross head self-tapping nail M3*10 6. LCD control switch 7. Cross countersunk head flat tail self-tapping nail M3*6 8. Cross head self-tapping ST5*25 9.
  • Page 11 JP Heater Depending on the actual installation, may only install three screws. Two die-cast aluminum fixing screws are fixed then choose a plastic right angle to fix it. To ensure that the heater evenly distributes heat, the heater should be installed in the center as much as...
  • Page 12 JP Heater To prevent the danger from heater accidentally The length of the intake and exhaust pipe is as shown in loosening, the upper cover of the heater compartment is Fig. 6, and the shortest is 60cm and the longest is screwed to the upper cover (Figure 4-1).
  • Page 13 JP Heater Select a flat mounting surface so that combustion air can enter from all sides. Drill one hole of φ83. Seal (Fig. 8-8), with the plane facing the exhaust cowl. Wear the fixing clip before installing the exhaust pipe (Figure 8-3). Pay Figure 9 attention to the installation of the smoke cap upwards。...
  • Page 14 φ65 bellows. Use only pressure piping that meets the higher than the connection of the warm air duct. When quality requirements of the JP. Other pipes that do not the pipe length is less than 50cm, the pipe must be meet our quality standards (especially wind resistance, siphon between the connector and the outlet.
  • Page 15 JP Heater The fuel is taken from the fuel tank of the vehicle or Oil pipeline installation supplied from a special 10L fuel tank. The fuel pump and The tubing must use the kit's accessories, which are fuel supply are adjusted by a special oil pump (provided nylon hoses that are resistant to light and heat.
  • Page 16 JP Heater If the lines are crossed, keep a sufficient distance from The difference in height between the fuel level and the the hot parts - if necessary, provide a thermal radiation oil pump and the height difference between the oil pump shield.
  • Page 17 JP Heater protection to seal the edges of the openings in the be vertically up (to ensure that the impurities are vehicle floor. To prevent the tubing and oil pump cable deposited downward). from being broken, add a bushing or cross-section edge The fuel filter replacement cycle is two years, and the protection material.
  • Page 18 JP Heater Water pipe connection Water can be supplied to the tank using a pressure pump or immersion pump with a pressure of 2.8 bar. If the tank is connected to a centralized supply (rural or urban connection), or if a high pressure pump is used, a pressure reducer must be used, which will prevent pressures above 2.8 bar.
  • Page 19 JP Heater For optimum room temperature control, install an external temperature sensor above the entrance door Figure 19 Make sure the external temperature sensor is always installed on the vertical wall. There must be free flowing Figure 20 air around it.
  • Page 20 JP Heater Figure 21 Figure 22 The connector cable and plug must be free of force. 1-DC12V positive 2-DC12V negative Bundling connector cable (See Figure 23), attach it to 3-Fuse 4-Window Switch the housing with a cable tie to eliminate tension.
  • Page 21 JP Heater Figure 23 DC12V Power Supply Figure 24 the heater's electrical wiring, switches, and control equipment must be in locations that would not adversely affect its operation under normal operating conditions. The heater has reverse polarity protection. If the controller is not connected correctly, the LED indicator Make sure the plug is securely connected.
  • Page 22 JP Heater...
  • Page 23 JP Heater 6. Operational Precautions Heating is not permitted during refueling or in confined spaces (closed parking lots, workshops or ferry cabin). Regularly check that the intake and exhaust pipes are in good condition and that the fixing is reliable, especially after a trip.
  • Page 24 JP Heater The Electrical Mode function has a mechanical overheat --Check if the exhaust cowl is unobstructed protection switch. -- Water tank filled with water when needed If the 12V power supply is interrupted during heating or Water filling after the heating process, the heater residual heat triggers the overheat protection switch.
  • Page 25 JP Heater - After the heater is turned off, the combustion-supporting fan and the heating fan will continue to operate for a few minutes depending on the temperature of the furnace. In case of freezing hazard, the water tank must be emptied.
  • Page 26 JP Heater 6. Failure 6.1 General Failure Handling 6.1.1 During the use of the heater, it may appear that it cannot start normally or turn off itself after starting and is in the fault lock state. At this time, the heater can be turned off for more than 5S and restart.
  • Page 27 JP Heater...
  • Page 28 JP Heater Fault Lock Status Debug Method Fault Code Fault Name Fault Debug Method Check gas supply system Combustion failure Check whether combustion inlet and outlet are blocked Check the flame sensor Check the flame sensor lead wire Flame sensor fault...
  • Page 29 JP Heater Fault Lock Status Debug Method Fault Fault Name Fault Debug Method Code Ignition coil fault Check ignition coil and lead wire High voltage power supply fault Replacement motherboard High voltage power supply fault Replacement motherboard Gas valve power failure...
  • Page 30 JP Heater 7. Operational Precautions Clean the external of heater ●Initial Installation Check the circuit connections for rust and looseness. – Flush the water tank with clean water before the heater Check whether the inlet and outlet of air is blocked or is first installed.
  • Page 31 JP Heater – During the transportation and storage process, the ambient temperature of the heater should not exceed - 40°C ~ 85°C to prevent damage to electronic components. – Only authorized customer service stations are allowed to install and repair heaters, and non-original parts are prohibited from danger.
  • Page 32 JP Heater Packing List Order Code Name Specification Quantity Instruction book YFY30-6E/1 22020202400 Heater E-Gas Hot Water/Warm Air Integrated 22020202700 Cross head self-tapping screw ST5*25 12050016100 Heater 12V Power cord 12031101600 External temperature sensor NTC10K 31011102100 LCD control switch MNB-V-FY...
  • Page 34 Date Repaired Items and Reason Month Year Month Year Month Year Month Year Month Year Month Year Month Year Month Year Month Year Month Year Month Year Month Year Month Year...

This manual is also suitable for:

4w200512c11

JP FJH-4/1C-E TECHNICAL DESCRIPTION, INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Pdf Download (2024)

References

Top Articles
Latest Posts
Article information

Author: Dong Thiel

Last Updated:

Views: 6420

Rating: 4.9 / 5 (59 voted)

Reviews: 90% of readers found this page helpful

Author information

Name: Dong Thiel

Birthday: 2001-07-14

Address: 2865 Kasha Unions, West Corrinne, AK 05708-1071

Phone: +3512198379449

Job: Design Planner

Hobby: Graffiti, Foreign language learning, Gambling, Metalworking, Rowing, Sculling, Sewing

Introduction: My name is Dong Thiel, I am a brainy, happy, tasty, lively, splendid, talented, cooperative person who loves writing and wants to share my knowledge and understanding with you.